Why Cyclone

CYCLONE, the Silent Force. 4-staged, air cooled, high pressure piston compressor, combining low turning speed operation, soundproof insulated doors, optimum cooling system, and easy-to-use digital control panel, providing smooth, safe, quiet and long life operation. Easy access through large openings ensuring quick maintenance. The multi stage purification system guarantees absolute clean air, making it applicable in numerous breathing air sectors including fish farms, military, fire brigades and diving centers.

The series consists of three versions:

  • Silent Electric- With soundproof insulation enabling it to operate in areas where the noise level is of issue. Includes digital control panel driving, controlling, protecting and ensuring the safe operation of the compressor.
  • Classic Diesel Stationary
  • Silent Electric ATEX -Exclusively designed for Explosive Environments

Why Cyclone

CYCLONE, the Silent Force. 4-staged, air cooled, high pressure piston compressor, combining low turning speed operation, soundproof insulated doors, optimum cooling system, and easy-to-use digital control panel, providing smooth, safe, quiet and long life operation. Easy access through large openings ensuring quick maintenance. The multi stage purification system guarantees absolute clean air, making it applicable in numerous breathing air sectors including fish farms, military, fire brigades and diving centers.

The series consists of three versions:

  • Silent Electric- With soundproof insulation enabling it to operate in areas where the noise level is of issue. Includes digital control panel driving, controlling, protecting and ensuring the safe operation of the compressor.
  • Classic Diesel Stationary
  • Silent Electric ATEX -Exclusively designed for Explosive Environments

“All Cyclone models are fully automated and provide 4-stages compression”

Classic Diesel

Technical Data

● Oil capacity: 2.1 lit special synthetic compressor oil.
● Permissible ambient temperature: +5 oC to +45 oC.
● Noise level: C. Silent 24 – 72 dB(A) @1m, C. Silent 30 – 73 dB(A) @1m, C. Silent 36 – 75 dB(A) @1m.
● ATEX version exclusively designed for explosive environments.

Design Specifications

cyclone

SILENT 24E,30E,36E

CLASSIC 24D

Star/Delta starter system

Electric Starting system with starter

Advanced DIGITAL CONTROLLER providing operation (running hrs, filling pressure, operating temperature), control (start/stop/reset/menu button) & service (service hrs-alarm, records of the last 15 malfunctions) data

Oil pump lubrication

Automatic stop system at the desirable pressure

Vibration Hourmeter / Service Timer (running Hours, BA Filter / Oil service hours)

Automatic condensate drains with manual backups + Condensate collecting tank

24V secondary voltage providing safety during routine operation

Main Switch & Emergency Stop button

Micronic air inlet filter

1,5m air inlet hose with particle strainer

Pressure maintaining & non return valve for extended filtration

Condensate Separators after 1st, 2nd, 3rd and final stage

Combined BA Filter including Coalescing Pre-filter (0.5 mg/m3 oil residual) and 2 large BA cartridges (AC/MS + HP option), with the supply of absolutely clean air exceeding by far the requirements of EN12021

Safety Bleed valve in case of BA Cartridge absence

High efficiency aluminium Intercooler (1st & 2nd stage)

Large Stainless Steel Intercooler (1st & 2nd stage)

Large Stainless Steel Intercooler – Aftercooler (3rd & 4th stage)

Safety Valves in all stages

Interstage pressure sensors providing emergency shutdown in case of overpressure

Secondary large fan with independent electric motor for optimum cooling (630mm diam.)

5 Kevlar filling hoses (1.2m each) with stainless steel fittings and DIN/INT’L connectors

Lever operated on/off filling valves with automatic ventilation

Soundproof insulation ensuring very low noise level

Dual pressure filling facility, allowing 225/330 bar simultaneous filling via pressure regulator

Remote Start/Stop – Remote Load/Unload

Interstage/Final stage Manometers

High Temperature monitoring / alarm / shutdown

Low Oil level monitoring / alarm / shutdown

Special Voltage/Frequency: 230V/50-60Hz * 3x230V/60Hz * 460-480V/60Hz

Voltage failure and Phase Rotation Safety device

Automatic belt tensioning system

Carbon Monoxide (CO) monitoring / alarm system / shutdown system

Hydrogen Sulfide (H2S) monitoring / alarm / shutdown system

Humidity (H2O) monitoring / alarm system / shutdown system

Carbon Dioxide (CO2) monitoring / alarm / shutdown system

OIL-VOC monitoring / alarm / shutdown system

Scroll to Top