Technical Data
Design Specifications
SILENT 24E,30E,36E |
CLASSIC 24D |
|
Star/Delta starter system |
|
|
Electric Starting system with starter |
|
|
Advanced DIGITAL CONTROLLER providing operation (running hrs, filling pressure, operating temperature), control (start/stop/reset/menu button) & service (service hrs-alarm, records of the last 15 malfunctions) data |
|
|
Oil pump lubrication |
|
|
Automatic stop system at the desirable pressure |
|
|
Vibration Hourmeter / Service Timer (running Hours, BA Filter / Oil service hours) |
|
|
Automatic condensate drains with manual backups + Condensate collecting tank |
|
|
24V secondary voltage providing safety during routine operation |
|
|
Main Switch & Emergency Stop button |
|
|
Micronic air inlet filter |
|
|
1,5m air inlet hose with particle strainer |
|
|
Pressure maintaining & non return valve for extended filtration |
|
|
Condensate Separators after 1st, 2nd, 3rd and final stage |
|
|
Combined BA Filter including Coalescing Pre-filter (0.5 mg/m3 oil residual) and 2 large BA cartridges (AC/MS + HP option), with the supply of absolutely clean air exceeding by far the requirements of EN12021 |
|
|
Safety Bleed valve in case of BA Cartridge absence |
|
|
High efficiency aluminium Intercooler (1st & 2nd stage) |
|
|
Large Stainless Steel Intercooler (1st & 2nd stage) |
|
|
Large Stainless Steel Intercooler – Aftercooler (3rd & 4th stage) |
|
|
Safety Valves in all stages |
|
|
Interstage pressure sensors providing emergency shutdown in case of overpressure |
|
|
Secondary large fan with independent electric motor for optimum cooling (630mm diam.) |
|
|
5 Kevlar filling hoses (1.2m each) with stainless steel fittings and DIN/INT’L connectors |
|
|
Lever operated on/off filling valves with automatic ventilation |
|
|
Soundproof insulation ensuring very low noise level |
|
|
Dual pressure filling facility, allowing 225/330 bar simultaneous filling via pressure regulator |
|
|
Remote Start/Stop – Remote Load/Unload |
|
|
Interstage/Final stage Manometers |
|
|
High Temperature monitoring / alarm / shutdown |
|
|
Low Oil level monitoring / alarm / shutdown |
|
|
Special Voltage/Frequency: 230V/50-60Hz * 3x230V/60Hz * 460-480V/60Hz |
|
|
Voltage failure and Phase Rotation Safety device |
|
|
Automatic belt tensioning system |
|
|
Carbon Monoxide (CO) monitoring / alarm system / shutdown system |
|
|
Hydrogen Sulfide (H2S) monitoring / alarm / shutdown system |
|
|
Humidity (H2O) monitoring / alarm system / shutdown system |
|
|
Carbon Dioxide (CO2) monitoring / alarm / shutdown system |
|
|
OIL-VOC monitoring / alarm / shutdown system |
|
|